MIL --- DTL --- 51523A(EA)
D. Run the sample immediately.
E. 1. For Type I dye report the percentages less than 850, 300 and 45 microns for the sam-
ple.
2. For Type II dye report the mean particle size, distribution shape and the percentage
below 10 microns for the sample.
4.4.3 Volatile matter. Weigh to the nearest milligram approximately 5g of the specimen in
a tared, glass --- stoppered weighing bottle. Remove the stopper and dry to constant weight at 70
to 75 C. Cool to room temperature in a desiccator and weigh. Calculate the percent by weight
volatile matter as follows:
Percent volatile matter = 100(A - B)∕W
where: A = Weight of specimen and stoppered bottle before heating in grams,
B = Weight of specimen and stoppered bottle after heating in grams, and
W = Weight of specimen before heating in grams.
4.4.4 Heavy metal contamination. Determine the heavy metals content of the sample in
accordance with EPA Method 6010B.
4.4.5 Apparent density. Determine the apparent density in accordance with ASTM D 1895,
Method A, except that the sample shall be dried as specified in 4.4.3 prior to testing.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified
in the contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD
or in --- house contractor personnel, these personnel need to contact the responsible packaging
activity to ascertain requisite packaging requirements. Packaging requirements are maintained
by the Inventory Control Point's packaging activities within the Military Service or Defense
Agency, or within the military service's system commands. Packaging data retrieval is available
from the managing Military Department's or Defense Agency's automated packaging files,
CD --- ROM products, or by contacting the responsible packaging activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful,
but is not mandatory.)
6.1 Intended use. Dye, Solvent Red 1, covered by this specification is intended for use in the
manufacture of colored signaling smoke mixtures.
6.2 Acquisition requirements. Acquisition documents should specify the following: